19-6 Configuring Alarm Inputs via Trigger Action Rules
LX Series Configuration Guide
3. Create rules to bind the trigger and the action:
Example InReach:0 >> config
Config:0 >> trigger
Trigger-Action:0 >> rule name pa10ctsh
Rule_pa10ctsh:0 >> trigger pa10ctsh
Rule_pa10ctsh:0 >> action pa10ctsh
Rule_pa10ctsh:0 >> exit
Trigger-Action:0 >> rule name pa10ctsl
Rule_pa10ctsl:0 >> trigger pa10ctsl
Rule_pa10ctsl:0 >> action pa10ctsl
Rule_pa10ctsl:0 >> end
InReach:0 >>
L The rules must be enabled. This will be shown later in
the setup sequence.
4. Create the SNMP Trap Client:
Example InReach:0 >> config
Config:0 >> snmp
Snmp:0 >> get client 0 x.x.x.x
Snmp:0 >> set client 0 x.x.x.x
Snmp:0 >> trap client 0 x.x.x.x
Snmp:0 >> exit
Config:0 >> snmp enable
Config:0 >> exit
InReach:0 >>
L x.x.x.x is the target SNMP management system
IP address.
5. Create the Notification Profile for the Service:
Example InReach:0 >> config
Config:0 >> notification
Notification:0 >> profile service ricksnmp snmp
Notification:0 >> end
InReach:0 >>
You can