Configuring Power Control Units
Specifying the 5250/5150/4800 Admin Name 10-11
X To specify the 5250/5150/4800 Admin Name
1. Access the Asynchronous Command Mode for an
asynchronous port that is configured as a POWER port for
a 5250/5150/4800 unit; for example:
Example Async7:0 >>access power
2. Use the power scp admin name command to specify the
Admin Name:
Example Async7:0 >>power scp admin name HenryK
In order to communicate to the 5250/5150/4800 unit, with scp
enable there must be an admin name and Password for the
5250/5150/4800 unit and 5250/5150/4800 authentication must
be enabled. For more information, see “Specifying the Password
for the 5250/5150/4800 Unit” on page 10-12.
This command can only be executed on a port that is configured
for 5250/5150/4800 power access and currently has a 5250/
5150/4800 unit connected to it. See “To configure an LX
asynchronous port as a POWER port” on page 10-2 to configure
an asynchronous port for 5250/5150/4800 power access.
This command configures the 5250/5150/4800 Admin Name for
both the port and the 5250/5150/4800 unit that is connected to
the port. If you connect the 5250/5150/4800 unit to another
port, you will need to re-specify the 5250/5150/4800 Admin
Name, and Password, for that port.
After the Admin Name and Login Password are configured, you
can enable authentication. For more information, see “Enabling
5250/5150/4800 Authentication” on page 10-13.