15-14 Resetting the Alarm Input Name to Its Default
LX Series Configuration Guide
Example
Resetting the Alarm Input Name to Its Default
Use the following commands to reset the Alarm Inputs to their
default names for a specific alarm or for multiple alarms.
X To reset the alarm input name to default for a
specific alarm
Use the following command syntax
Syntax hdam alarm <alarm_name> default name
X To reset the alarm input name to default for
multiple alarms
Use the following command syntax:
Syntax hdam alarm port <port_number> slot [<slot_list>|all]
point [<
point_list>|all]default name
where
Config:0 >>hdam alarm SafedepositDoor trap severity critical
Config:0 >>hdam alarm 5_2_31 trap severity informational
Config:0 >>hdam alarm port 2 slot 1,2 point 1,2,3,4 trap severity mino
Config:0 >>hdam alarm port 2 slot 1-4 point 6-18 trap severity major
alarm_name The name of the alarm which you want to set to its
default name. This entry is in the order port_slot_alarm
(e.g., 5_2_31, or BankVaultDoor). The value of alarm_
name can be a descriptive name or a default name.
port_number Specifies the LX HDAM port managing the 7204T.
slot_list Specifies a list of Slots whose points to reset to the
default name. The list can contain single items, lists
(such as 1,3,4) or ranges (such as 1-4), or a
combination.
point_list Specifies a list of Points to reset to the default name.
The list can contain single items, lists (such as 1,3,4) or
ranges (such as 1-32), or a combination.
all
The default command will apply to all Slots or Points (or
both) managed by this LX Master Unit.
Commentaires sur ces manuels